INVERTER MODULE |
|
MODEL |
RS 3.6 HYBRID |
EFFICIENCY |
|
Maximum efficiency [%] (PV to Grid) |
95.7 |
Maximum efficiency [%] (AC to BAT) |
92.3 |
Maximum efficiency [%] (BAT to AC) |
92.6 |
Rated battery voltage [V] |
51.2 |
Allowable battery voltage range [V] |
40 - 60 |
Maximum charge/discharge current [A] |
60 / 60 |
INPUT |
|
Maximum PV input power [W] |
9000 (4500 / 4500) |
Maximum PV input voltage [V] |
550 |
Minimum PV input voltage [V] |
70 |
Rated PV Input Voltage [V] |
360 |
Maximum input current (input A/input B) [A] |
15 / 15 |
Maximum short circuit current (input A/input B) [A] |
20 / 20 |
Starting operating voltage [V] |
90 |
Rango de tensión de funcionamiento MPPT [V] |
90 ÷ 520 |
Number of MPPT trackers |
2 |
String per MPP tracker |
1 |
OUTPUT |
|
Rated AC output power [W] |
3600 |
Maximum apparent AC power [VA] |
3960 |
Maximum active AC power (PF=1) [W] |
3600 |
Maximum current AC output [A] |
18 |
Nominal output voltage [V] |
230 |
Output voltage range [V] |
230 ±5% |
Grid voltage range [V] |
176 ÷ 264 (according to local standard) |
Rated Grid Frequency [Hz] |
50 / 60 |
Grid frequency range [Hz] |
45-55 / 55-65 |
Current Harmonic Distorsion (THDi) [%] |
<5 (nominal power) |
Direct current injection [%] |
<0.5 In |
Power factor |
1 @ rated power (adjustable 0.8 inductive – 0.8 capacitive) |
BACKUP |
|
Nominal output voltage[V] |
230 |
Output voltage range[V] |
230 ±5% |
Nominal output frequency(Hz) |
50 / 60 |
Output frequency range(Hz) |
50 / 60 (±0.2%) |
Nominal output power [VA] |
3600 |
Nominal output power [W] |
2800 @ 51.2 V battery voltage |
Nominal output current [A] |
15.6 |
Output voltage DC component [mV] |
≤200 |
Output overload capacity |
≥105% for 1s |
Transfer time [ms] |
10 (typical), 20 (maximum) |
THDV [%] |
<3 (Rated R Load) |
OVERALL SPECIFICATION |
|
Type |
Transformerless |
Protection level |
IP65 |
Overvoltage category battery input |
I |
Overvoltage category PV input |
II |
Overvoltage category AC output |
III |
Protection class |
I |
Battery overcurrent protection |
DC Circuit Breaker |
Pollution degree |
PDIII acc. IEC60664-1 (internal reduced to PDII) |
Cooling |
Natural cooling |
Operating temperature range [°C] |
-25 ÷ 60 (up to 40 °C without derating) |
Storage temperature range [℃] |
-30 ÷ 65 |
Relative humidity range [%] |
0 ÷ 95 |
Maximum Operating Altitude [m] |
4000 (up to 2000 without derating) |
Noise level [dB] (@ 1m) |
<30 |
Dimensions (WxDxH) [mm] |
610x232x458 |
Weight [Kg] |
26.6 |
Weight (packed) [Kg] |
46 |
PV connection |
MC4 / H4 |
Battery connection |
Dedicated DC connector |
AC connection way (grid & back up) |
Dedicated AC connector |
BATTERY MODULE |
|
MODEL |
RS BATLIO 5120 |
Battery type |
LFP (LiFePO4) |
Rated battery voltage [V] |
51.2 |
Battery voltage range [V] |
44.8 ÷ 58.4 |
Battery module energy [kWh] |
5.12 |
Maximum charge/discharge current [A] |
100 / 100 |
Maximum modules in paralles [Pcs] |
6 |
Operating temperature range for charge [C°] |
0 ÷ 45 |
Operating temperature range for discharge [C°] |
-20 ÷ 55 |
Number of cycles |
≥4000 |
Dimensions (WxDxH) [mm] |
610x252x330 |
Weight (net) [Kg] |
54.5 |
Overcurrent protection |
DC Circuit Breaker |
Communication protocol |
CAN |
Certification |
IEC 62619:2017; EN 62619:2017; IEC 61000-6/2/4:2019; UN 38.3: Rev.7 |
COMMUNICATION |
|
Display |
APP + LED |
Communication |
RS485 / Bluetooth / WIFI / Ethernet (optional) |
CERTIFICATES |
|
Grid |
CEI0-21:2022; NTS Type A 2.0 (UNE 217002:2020; RD647:2020), UNE 217001: 2020/RD244: 2019 |
Safety |
IEC/EN 62109-1: 2010; IEC/EN 62109-2: 2011; IEC 62040-1:2017 |
EMC |